{"id":27784,"date":"2025-04-30T13:50:10","date_gmt":"2025-04-30T11:50:10","guid":{"rendered":"https:\/\/ai.lukasiewicz.gov.pl\/laboratoria\/cable-and-environmental-testing-laboratory\/"},"modified":"2026-07-08T12:55:34","modified_gmt":"2026-07-08T10:55:34","slug":"cable-and-environmental-testing-laboratory","status":"publish","type":"laboratoria","link":"https:\/\/ai.lukasiewicz.gov.pl\/en\/laboratoria\/cable-and-environmental-testing-laboratory\/","title":{"rendered":"Cable and Environmental Testing Laboratory"},"content":{"rendered":"","protected":false},"featured_media":15307,"template":"","class_list":["post-27784","laboratoria","type-laboratoria","status-publish","has-post-thumbnail","hentry"],"acf":{"kontakt":"<p><a href=\"tel:+48322007516\"><span data-mce-type=\"bookmark\" style=\"width: 0px;overflow: hidden;line-height: 0\" class=\"mce_SELRES_start\">\ufeff<\/span>+48 32 2007 516<\/a>, <a href=\"tel:+48322007512\">+48 32 2007 512<\/a><br \/>\n<a href=\"mailto:lab_zlk@ai.lukasiewicz.gov.pl\">lab_zlk@ai.lukasiewicz.gov.pl<\/a><\/p>\n","tresc_glowna":"<p>The key areas of its activity are:<\/p>\n<ul>\n<li>Testing of low and medium voltage cables and wires.<\/li>\n<li>Environmental testing.<\/li>\n<li>IP protection rating testing.<\/li>\n<\/ul>\n<p><span data-contrast=\"none\"><span class=\"TextRun Underlined SCXW191168644 BCX0\" lang=\"PL-PL\" data-contrast=\"none\"><span class=\"NormalTextRun SCXW191168644 BCX0\">Testing of low and medium voltage cables and wires.<\/span><\/span><strong><span class=\"EOP SCXW191168644 BCX0\" data-ccp-props=\"{\"134233117\":true,\"134233118\":true,\"201341983\":0,\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":257}\"><br \/>\n<\/span><\/strong><\/span><\/p>\n<ul>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"51\" data-list-defn-props=\"{\"335552541\":1,\"335559684\":-2,\"335559685\":720,\"335559991\":360,\"469769226\":\"Symbol\",\"469769242\":[8226],\"469777803\":\"left\",\"469777804\":\"\uf0b7\",\"469777815\":\"hybridMultilevel\"}\" data-aria-posinset=\"1\" data-aria-level=\"1\"><span data-contrast=\"none\">Electrical (e.g., insulation resistance measurements, insulation strength tests, or capacitance measurements)<\/span><span data-ccp-props=\"{\"134233117\":true,\"134233118\":true,\"201341983\":0,\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":257}\"> <\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"51\" data-list-defn-props=\"{\"335552541\":1,\"335559684\":-2,\"335559685\":720,\"335559991\":360,\"469769226\":\"Symbol\",\"469769242\":[8226],\"469777803\":\"left\",\"469777804\":\"\uf0b7\",\"469777815\":\"hybridMultilevel\"}\" data-aria-posinset=\"2\" data-aria-level=\"1\"><span data-contrast=\"none\">Mechanical (e.g., testing tensile strength and elongation at break, tests for winding and impact resistance, or bending resistance)<\/span><span data-ccp-props=\"{\"134233117\":true,\"134233118\":true,\"201341983\":0,\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":257}\"> <\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"51\" data-list-defn-props=\"{\"335552541\":1,\"335559684\":-2,\"335559685\":720,\"335559991\":360,\"469769226\":\"Symbol\",\"469769242\":[8226],\"469777803\":\"left\",\"469777804\":\"\uf0b7\",\"469777815\":\"hybridMultilevel\"}\" data-aria-posinset=\"3\" data-aria-level=\"1\"><span data-contrast=\"none\">Physical properties (e.g., dimension checks or heating tests).<\/span><span data-ccp-props=\"{\"134233117\":true,\"134233118\":true,\"201341983\":0,\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":257}\"> <\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"51\" data-list-defn-props=\"{\"335552541\":1,\"335559684\":-2,\"335559685\":720,\"335559991\":360,\"469769226\":\"Symbol\",\"469769242\":[8226],\"469777803\":\"left\",\"469777804\":\"\uf0b7\",\"469777815\":\"hybridMultilevel\"}\" data-aria-posinset=\"4\" data-aria-level=\"1\"><span data-contrast=\"none\">Fire resistance (e.g., testing oxygen index or flame spread). <\/span><span data-ccp-props=\"{\"134233117\":true,\"134233118\":true,\"201341983\":0,\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":257}\"> <\/span><\/li>\n<\/ul>\n<p>Environmental testing:<\/p>\n<ul>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"52\" data-list-defn-props=\"{\"335552541\":1,\"335559684\":-2,\"335559685\":720,\"335559991\":360,\"469769226\":\"Symbol\",\"469769242\":[8226],\"469777803\":\"left\",\"469777804\":\"\uf0b7\",\"469777815\":\"hybridMultilevel\"}\" data-aria-posinset=\"1\" data-aria-level=\"1\"><span data-contrast=\"none\">Cold and heat,<\/span><span data-ccp-props=\"{\"134233117\":true,\"134233118\":true,\"201341983\":0,\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":257}\"> <\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"52\" data-list-defn-props=\"{\"335552541\":1,\"335559684\":-2,\"335559685\":720,\"335559991\":360,\"469769226\":\"Symbol\",\"469769242\":[8226],\"469777803\":\"left\",\"469777804\":\"\uf0b7\",\"469777815\":\"hybridMultilevel\"}\" data-aria-posinset=\"2\" data-aria-level=\"1\"><span data-contrast=\"none\">Constant and cyclic humidity,<\/span><span data-ccp-props=\"{\"134233117\":true,\"134233118\":true,\"201341983\":0,\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":257}\"> <\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"52\" data-list-defn-props=\"{\"335552541\":1,\"335559684\":-2,\"335559685\":720,\"335559991\":360,\"469769226\":\"Symbol\",\"469769242\":[8226],\"469777803\":\"left\",\"469777804\":\"\uf0b7\",\"469777815\":\"hybridMultilevel\"}\" data-aria-posinset=\"3\" data-aria-level=\"1\"><span data-contrast=\"none\">Temperature changes (including thermal shock),<\/span><span data-ccp-props=\"{\"134233117\":true,\"134233118\":true,\"201341983\":0,\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":257}\"> <\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"52\" data-list-defn-props=\"{\"335552541\":1,\"335559684\":-2,\"335559685\":720,\"335559991\":360,\"469769226\":\"Symbol\",\"469769242\":[8226],\"469777803\":\"left\",\"469777804\":\"\uf0b7\",\"469777815\":\"hybridMultilevel\"}\" data-aria-posinset=\"4\" data-aria-level=\"1\"><span data-contrast=\"none\">Low pressure, <\/span><span data-ccp-props=\"{\"134233117\":true,\"134233118\":true,\"201341983\":0,\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":257}\"> <\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"52\" data-list-defn-props=\"{\"335552541\":1,\"335559684\":-2,\"335559685\":720,\"335559991\":360,\"469769226\":\"Symbol\",\"469769242\":[8226],\"469777803\":\"left\",\"469777804\":\"\uf0b7\",\"469777815\":\"hybridMultilevel\"}\" data-aria-posinset=\"5\" data-aria-level=\"1\"><span data-contrast=\"none\">Vibration and mechanical shock,<\/span><span data-ccp-props=\"{\"134233117\":true,\"134233118\":true,\"201341983\":0,\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":257}\"> <\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"52\" data-list-defn-props=\"{\"335552541\":1,\"335559684\":-2,\"335559685\":720,\"335559991\":360,\"469769226\":\"Symbol\",\"469769242\":[8226],\"469777803\":\"left\",\"469777804\":\"\uf0b7\",\"469777815\":\"hybridMultilevel\"}\" data-aria-posinset=\"1\" data-aria-level=\"1\"><span data-contrast=\"none\">Spring hammer impacts,<\/span><span data-ccp-props=\"{\"134233117\":true,\"134233118\":true,\"201341983\":0,\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":257}\"> <\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"52\" data-list-defn-props=\"{\"335552541\":1,\"335559684\":-2,\"335559685\":720,\"335559991\":360,\"469769226\":\"Symbol\",\"469769242\":[8226],\"469777803\":\"left\",\"469777804\":\"\uf0b7\",\"469777815\":\"hybridMultilevel\"}\" data-aria-posinset=\"2\" data-aria-level=\"1\"><span data-contrast=\"none\">Salt mist (non-accredited).<\/span><span data-ccp-props=\"{\"134233117\":true,\"134233118\":true,\"201341983\":0,\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":257}\"> <\/span><\/li>\n<\/ul>\n<p>IP protection rating testing:<\/p>\n<ul>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"47\" data-list-defn-props=\"{\"335552541\":1,\"335559684\":-2,\"335559685\":720,\"335559991\":360,\"469769226\":\"Symbol\",\"469769242\":[8226],\"469777803\":\"left\",\"469777804\":\"\uf0b7\",\"469777815\":\"hybridMultilevel\"}\" data-aria-posinset=\"1\" data-aria-level=\"1\"><span data-contrast=\"none\">Testing protection against solid foreign objects and access to hazardous parts from IP3X to IP6X,<\/span><span data-ccp-props=\"{\"134233117\":true,\"134233118\":true,\"201341983\":0,\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":257}\"> <\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"47\" data-list-defn-props=\"{\"335552541\":1,\"335559684\":-2,\"335559685\":720,\"335559991\":360,\"469769226\":\"Symbol\",\"469769242\":[8226],\"469777803\":\"left\",\"469777804\":\"\uf0b7\",\"469777815\":\"hybridMultilevel\"}\" data-aria-posinset=\"2\" data-aria-level=\"1\"><span data-contrast=\"none\">Testing protection against water ingress from IPX1 to IPX9k. <\/span><span data-ccp-props=\"{\"134233117\":true,\"134233118\":true,\"201341983\":0,\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":257}\"> <\/span><\/li>\n<\/ul>\n<p><span data-contrast=\"none\">A detailed description of the testing methods can be found in the PCA accreditation scope No. AB 261.<\/span><span data-ccp-props=\"{\"134233117\":true,\"134233118\":true,\"201341983\":0,\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":257}\"> <\/span><\/p>\n","dodatkowy_opis":"<p>The laboratory is equipped with, among others:<\/p>\n<ul>\n<li>Angelantoni ACS WZH 30 climate chamber with a capacity of 30 m\u00b3, featuring a temperature range from -70\u00b0C to 80\u00b0C and humidity up to 95% RH.<\/li>\n<li>Angelantoni ANYVIB 1200 climate chamber with a capacity of 1 m\u00b3, offering a temperature range from -70\u00b0C to 180\u00b0C and humidity up to 98% RH. It is compatible with a vertical axis vibration system.<\/li>\n<li>Climats TAH 1000 pressure (vacuum) climate chamber with a capacity of 1 m\u00b3, featuring a temperature range from -70\u00b0C to 100\u00b0C, humidity up to 95% RH, and pressure adjustable from atmospheric level to 10 mBar.<\/li>\n<li>Climats SCAL 1000 shock climate chamber with a capacity of 1 m\u00b3, equipped with a hot chamber that maintains temperatures from 60\u00b0C to 200\u00b0C and a cold chamber with a range from -85\u00b0C to 180\u00b0C (which also functions as a stand-alone rapid climate chamber). It includes an elevator for quick transfer between chambers.<\/li>\n<li>TIRA TV59349 vibration system with a nominal force of 99,000 N for mechanical shocks and 49,500 N for vibrations. It is equipped with a slip table and allows vibration and mechanical shock testing in three perpendicular axes.<\/li>\n<li>King Design ST-8010 gravitational shock system that enables vertical axis mechanical shocks with acceleration up to 15,000 m\/s\u00b2 (and up to 100,000 m\/s\u00b2 for small objects with the appropriate attachment)<\/li>\n<li>Angelantoni DCTC 1200 salt spray chamber with a usable capacity of 955 liters, designed for corrosion testing in salt spray (NaCl) environments at temperatures from ambient conditions to 55\u00b0C, with constant humidity up to 98% RH.<\/li>\n<li>The Angelantoni SD 1000 dust chamber with a capacity of 1 m\u00b3, along with the accompanying test station and probe set, enables testing of protection levels from IP3X to IPX9K.<br \/>\nThe water testing station allows for protection level testing from IPX1 to IPX9K.<\/li>\n<li>Milli-To 3 high-precision ohmmeter for measuring resistance from 1 m\u2126 to 100 T\u2126 (with a measurement voltage up to 500 V DC).<\/li>\n<li>Voltage devices enabling insulation testing with voltages up to 75 kV AC at 50 Hz and 6 kV DC.<\/li>\n<li>Precision temperature meters and recorders with a measurement range from -70\u00b0C to 250\u00b0C.<\/li>\n<\/ul>\n","odbiorcy_uslugi":"Testing of low- and medium-voltage cables and wires is intended for leading manufacturers of cables and wire products.\nEnvironmental testing services are dedicated to manufacturers operating in the railway industry, companies within the automotive sector, and manufacturers of batteries and lithium-ion cells.","zakres_akredytacji":"AB 261"},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/ai.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/laboratoria\/27784","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ai.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/laboratoria"}],"about":[{"href":"https:\/\/ai.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/types\/laboratoria"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ai.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/media\/15307"}],"wp:attachment":[{"href":"https:\/\/ai.lukasiewicz.gov.pl\/en\/wp-json\/wp\/v2\/media?parent=27784"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}